LGaN
Revision 0
Serial Interface Operation
5–21
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Maximum
Operating
Points
(Cont)
10-06-19 09:48:17 MAX PS AC WATT=83080.8
10-06-19 09:57:41 MIN PS AC WATT=83073.4
10-06-19 09:48:23 MAX PS AC LINE=60.03
10-06-19 09:59:36 MIN PS AC LINE=59.98
Unit Alarm
Mask
MSK=
7 bytes
Command or Query.
Alarm mask conditions. If the mask value for a certain parameter is
set to fault, then a fault condition will be registered if specified
hardware conditions are not met. If the mask value is set to alarm,
then a fault condition will only appear to be an alarm that will not set
the summary fault relay. If the mask value is set to masked, then the
fault will never be reported to the user.
Form of: abcdef
Where:
0 = Fault
1 = Alarm
2 = Masked
a = RF Fan 1 Speed
b = RF Fan 2 Speed
c = PS Fan Speed
d = Input Power
e = Reverse Power
f = Low Forward Power
g = High Forward Power
h = External Reference Lock detect
i = LNB Current Detect
j = LNB 22V Power Supply
Example:
<0001/MSK=1112022222’cr’
>0001/MSK=’cr’’lf’
Default Value: 1112022222
MSK=
MSK?
MSK*
MSK?
MSK=abcdef
(See
description for
details of
arguments)
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...