LGaN
Revision 0
System Connectors, Installation, and Startup
2–6
MN-LGAN
2.3.3 Connector ‘J3 | POWER IN’
2.3.3.1
Connector ‘J3 | POWER IN’ AC Power Main – 100 W
The mating connector specification and pin assignments specific to the LGaN 100 W
power interfaces are as follows:
Mating Connector:
Glenair ITS-3106F20-19SF7
(CEFD PN CN/MS-STPG03F07)
Table 2-1. Connector ‘J3 | POWER IN’ Pin Assignments – 100 W
Pin
Description
A
GND
B
NEUTRAL (L2)
C
LINE (L1)
2.3.3.2
Connector ‘J3 | POWER IN’ DC Power Mains
FOR SAFETY REASONS, MAKE SURE YOU KNOW THAT THE ‘J3 | POWER IN’ DC
POWER CONNECTION PIN ASSIGNMENTS ARE DIFFERENT FOR EACH LGAN UNIT.
YOU MUST USE THE CORRECT PIN ASSIGNMENTS.
INCORRECT USE OF PIN ASSIGNMENTS CAN RESULT IN PRODUCT DAMAGE OR
PERSONAL INJURY.
The prime power input requirement for the for the LGaN 50 W is 36 to 60 VDC and for the LGaN 100 W is
36 to 72 VDC. The total power required from the prime power supply depends on the model used. See
Sect. 1.5 Summary of Specifications
for more information.
2.3.3.2.1
Connector ‘J3 | POWER IN’ DC Power Main – 50 W
The mating connector specification and the pin assignments (Table 2-2) specific to the
LGaN 50 W DC power interface are as follows:
Mating Connector:
SOURIAU #UTS6GJC104S
(CEFD PN CN-0021091)
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...