LGaN
Revision 0
Serial Interface Operation
5–12
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Attenuation
ATT=
5 bytes
Command or Query.
Set the RF attenuation level from 0 to 10dB in 0.25dB steps.
Example:
<1/ATT=10.00’cr’
>0001/ATT=’cr’’lf’
Default Value: 10.00
Default ATT Step: 0.25 dB
ATT=
ATT?
ATT*
ATT?
ATT=xx.xx
(Same format
as command
arguments)
Auxiliary Mute
AUX=
1 byte
Command or Query.
Enable or disable the auxiliary mute hardware control.
Where:
1 = auxiliary mute enabled
0 = auxiliary mute disabled
Example:
<1/AUX=1’cr’
>0001/AUX=’cr’’lf’
Default Value: 0
AUX=
AUX?
AUX*
AUX?
Clear All Stored
Alarms
CAA=
None
Command only.
Instructs the unit to clear all Stored Alarms. This command takes no
arguments.
Example:
<1/CAA=’cr’
>0001/CAA=’cr’’lf’
CAA=
CAA*
N/A
N/A
Clear All Stored
Events
CAE=
None
Command only.
Clear all Stored Events. This command takes no arguments.
Example:
<1/CAE=’cr’
>0001/CAE=’cr’’lf’
CAE=
CAE*
N/A
N/A
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...