DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Serial Interface Operation
Revision 2
8–33
8.8
Error Processing
8.8.1.1
General Errors
Any command or query may generate the following Error Responses instead of a
confirmation:
>DEV?COM CU CMD UNRECOGNIZED{cr}{lf}]
>DEV?COM IP INVALID PARAM{cr}{lf}]
>DEV?COM PE PARITY ERROR{cr}{lf}]
8.8.1.2
Configuration Errors
A Configuration command may generate the following Error Response:
>DEV?COM LO DEVICE IN LOCAL MODE{cr}{lf}]
8.8.1.3
Mode Errors
A Mode selection may generate the following Error Responses:
>DEV?COM AE ONLY VALID WHEN BACKUP{cr}{lf}]
>DEV?COM OE OFFLINE NOT AVAILABLE{cr}{lf}]
>DEV?COM CN COMMAND NOT AVAILABLE{cr}{lf}]
8.8.1.4
Time-Outs
The station M&C computer should attempt to execute any instruction at least
three times. The system assumes a time-out if there is no response within 500
milliseconds.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...