DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Front Panel Operation
Revision 2
6–16
On the bottom line, use the
keys to navigate to the
ACTIVATE BACKUP
setting, and then use the
keys to set toggle switchover as
NO
(i.e., no
backup occurs at the defined operational threshold), or
FORCE
(i.e., switchover
occurs automatically if operation exceeds the predefined operational threshold).
Note that this submenu is operational only with a backup unit assigned, and with
the switchover set as
Auto
matic
.
In the absence of a designated backup unit
and/or switchover set as
Man
ual, this message displays:
NO UNITS CURRENTLY
BACKED UP OR IN MANUAL
Press
ENTER
or
CLEAR
to return to the previous menus, and then reconfigure the
system to operate as intended.
6.2.3.3.4
(REDUNDANCY:) HSB
CONV# 01 FRQ= 3625.000
ATTN=00.00 AUTO OK
In the "Daisy Chain" configuration, the BU communicates with the online units
through the HSB (high-speed bus data interface). The BU detects faults and
reconfigures itself to replace the faulted converter. The BU also uses the HSB to
monitor configuration changes made to an online converter. Changes in
frequency, gain, or polarity are immediately entered into the backup table as
well as information from new online units. The HSB does not interfere with the
remote serial communication link access to any of the converters in the chain.
Use the HSB submenu to configure operation of the ‘J3 | HSB’ connector that is
provided on the optional Receive Switch Module (RSM) and Transmit Switch
Module (TSM). When an RSM or TSM is not configured for operation, this
message displays:
CONV #01 – NO DATA
HSB NO RESPONSE
Press
ENTER
or
CLEAR
to continue.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...