RF Converter Module
IFLO Lock Detect:
A fault (“FT”) indicates that the IFLO is not locked. Check all
connections to the converter module to make sure they are secure. If the fault still
exists, remove the module and return it to Comtech EF Data for repair.
B.2.3.4
Synthesizer Sum Loop Module
Sum Loop Detect:
A fault (“FT”) indicates that the sum loop is not locked. Check
all connections to the converter module to make sure they are secure. If the fault
still exists, remove the Sum Loop Module and return it to Comtech EF Data for
repair.
B.2.3.5
Synthesizer Fine Step Module
Coarse Loop Detect:
A fault (“FT”) indicates that the coarse loop is not locked.
Check all connections to the converter module to make sure they are secure. If the
fault still exists, remove the Fine Step Module and return it to Comtech EF Data for
repair.
Fine Loop Detect:
A fault (“FT”) indicates that the fine loop is not locked. Check all
connections to the converter module to make sure they are secure. If the fault still
exists, remove the Fine Step Module and return it to Comtech EF Data for repair.
B.2.3.6
Reference Oscillator Module
Reference Lock Detect:
A fault ("FT") indicates that the reference oscillator
detected an external reference, but could not lock to it. Disconnect the external
reference. If the fault still exists, remove the Reference Module and return it to
Comtech EF Data for repair.
B.2.3.7
Temperature Fault
Converter Over Temperature Fault:
A fault ("FT") indicates that the converter is
over temperature. Turn the prime power switch off and return the converter to
Comtech EF Data for repair.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...