DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Appendix B
Revision 2
B–6
B.3
Spares
Comtech EF Data recommends that you have spare replacement converters on
hand at the RF converter level to replace any converter(s) removed from the
system for any reason.
If sparing at a lower level is desired, contact Comtech EF Data Product Support
for the correct spares for your particular converter.
B.4
Redundancy Systems – Converter Management
B.4.1
Remove a Faulted Converter
To remove a faulted “inline” converter for repair, do these steps:
1.
Force a backup of the faulted unit.
2.
Turn OFF the power to the faulted unit at the rear panel power switch
and disconnect the power cord. (DO NOT disconnect the RF and IF cables
from the Receive Switch Module (RSM).)
3.
Unscrew the faulted unit RSM thumbscrews. Then, remove the rack
mounting screws at the front panel of the faulted unit.
4.
From the rear of the faulted unit, hold the RSM, and push the chassis
towards the front of the rack until the module fully detaches from the
unit. Leave the RSM “dangle” by its connected cables.
5.
Remove the faulted unit from the front of the rack.
To remove a faulted “backup” converter for repair, do these steps:
1.
Turn OFF the power to the faulted BU at its rear panel power switch.
2.
Remove the power cord from the faulted BU.
3.
Disconnect the RF and IF cables from the faulted BU’s IOM.
4.
Remove the rack mounting screws at the front panel of the faulted BU.
5.
Remove the faulted BU from the front of the rack.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...