DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Appendix B
Revision 2
B–7
B.4.2
Install a Replacement Converter
To install a replacement converter into your redundancy system, do these steps:
1.
With the replacement unit on the bench, turn ON the unit power.
2.
Configure the new unit for the correct redundancy settings:
a.
Set Redundant Mode = ON;
b.
Set the Address (Chain Position) to match the faulted unit;
c.
Set the correct frequency and attenuation.
3.
Turn OFF the replacement unit power and disconnect the power cord.
4.
Remove the existing module (IOM, RSM, TSM, etc.) from the new unit.
5.
Carefully install the new unit into the rack.
6.
Plug the existing module in the rack into the replacement unit, and
finger-tighten the module thumbscrews.
7.
Plug the power cord back into the replacement unit, and turn the power
ON.
8.
Un-force the backup.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...