DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Appendix A
Revision 2
A–3
Options for the RSM include Type ‘SMA’ female connectors for the RF Input
signal, and 50
Ω or 75Ω BNC female connectors for the IF output.
The "Daisy Chain" configuration is designed to chain the IF output of up to twelve
(12) online converters through RSMs terminating in a BU. When a fault occurs in
an online converter, the system commands the RSM in the faulted converter to
switch to the BU.
A.3
Redundant Configurations
You may configure the DT-4500 in a variety of subsystem "Daisy Chain"
configurations to suit the reliability requirements of your communication
system. These configurations include 1:1 or 1:N Redundant Systems.
A.3.1
1:1 Redundant Systems
A 1:1 Redundant System can be either a Single Source or a Dual Source IF Output
Configuration.
In a Single Source IF Output Configuration: Figure A-1
connections between the converters.
shows the diagram for this 1:1
redundant converter configuration.
The online converter uses an IF transfer switch to switch the IF signal. A single
switched IF output is provided to and from the online converter. The transfer
switches are contained in the RSM installed in the online converter. When a fault
occurs in the online converter, the RSM is de-activated to switch out the online
converter, and switch the IF output to the BU.
In a Dual Source IF Output Configuration: Figure A-5
connections between the converters.
redundant/dual source RF input/converter configuration.
Two IF outputs – IF Output #1 (priority) and IF Output #2 – are switched in the
RSM to provide redundant operation of the converters. The converters provide
two switched IF outputs – IF Output #1 (priority) and IF Output #2. If Converter
#01 faults, Converter #02 backs up the priority channel and IF Signal #2 is not
operational.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...