DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Front Panel Operation
Revision 2
6–15
Note the following:
•
With
CONVERTER = #BU
, the unit is set as the standby, or backup unit.
This mode of operation is indicated on the right-hand side of the bottom
line as
1:0#
.
•
With
CONVERTER = #01-12
, the selected unit is set as the primary
operating unit. The mode of operation is indicated on the right-hand side
of the bottom line as
POL=1
.
6.2.3.3.2
(REDUNDANCY:) Auto/Manual
CONVERTER 123456789ABC
AUTO/MAN A-----------
Use this submenu to define backup as
Auto
(Automatic) or
MAN
(manual). This
setting allows automatic switching by the BU if both units are in Redundancy
Mode.
This command is only accepted by the BU. If a chain converter is set to Manual
Mode, the BU logs the occurrence and does not act upon further information
from the converter until it is returned to Auto Mode.
On the top line, this line displays the unit in use and its Application ID
(identification label).
On the bottom line, use the
keys to navigate to the
AUTO/MAN
setting,
and then use the
▲
▼
keys to set toggle switch over as
A
(Automatic) or
M
(Manual).
6.2.3.3.3
(REDUNDANCY:) FORCE
CONV 01 00.00 DB
ACTIVATE BACKUP = NO
On the top line, use the
keys to navigate to the
OFFSET
operational
threshold setting (i.e., the limit defined to automatically trigger switchover to the
backup unit), and then use the
keys to set that value in 0.25 dB increments.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...