CoNTaCT ClosuRes seTTINgs
Connect on CC (1,2,3,4)
- These choices define auto connect rules for remotes to be triggered by the four external
input triggers available. NOTE: These inputs are shared with the end-to-end contact closure signals, so if a remote
is designated as
Auto Connect
on a closure, that closure signal is not available for use in the direction from this
ACCESS. To assign a remote connection to a contact closure, pull down the menu box next to the desired closure
and select the proper remote. A connection attempt will be made whenever the contact is triggered, and will
disconnect whenever the contact is released. (You can also assign the
F2
key to trigger
Contact Closure #1
at the
remote codec.)
Activate contact closure 4 output when connected
- Under normal circumstances, the contact will close when
commanded by the other end of the connection. If this option is enabled, that function is no longer available. This
contact will be closed when a valid connection is present, and open when no connection is present.