Error messages 96
Accelerator Status: Warranty Alert
Description
: Catastrophic problem exists with array accelerator board. Refer to other messages on
Diagnostics screen for exact meaning of this message.
Action
: Replace the array accelerator board.
Adapter/NVRAM ID Mismatch
Description
: EISA NVRAM has an ID for a different controller from the one physically present in the slot.
Action
: Run the server setup utility.
Array Accelerator Battery Pack X not Fully Charged
Description
: Battery is not fully charged.
Action
: If 75% of the batteries present are fully charged, the array accelerator is fully operational. If more
than 75% of the batteries are
not
fully charged, allow 36 hours to recharge them.
Array Accelerator Battery Pack X Below Reference Voltage (Recharging)
Description
: Battery pack on the array accelerator is below the required voltage levels.
Action
: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.
Board in Use by Expand Operation
Description
: Array accelerator memory is in use by a capacity expansion or RAID migration.
Action
: The array accelerator is automatically re-enabled for caching when the capacity expansion or RAID
operation completes.
Board not Attached
Description
: An array controller is configured for use with array accelerator board, but one is not connected.
Action
: Connect array accelerator board to array controller.
Cache Has Been Disabled Because ADG Enabler Dongle is Broken or Missing
Description
: The cache has been disabled because RAID ADG volume is configured but the ADG Enabler
Dongle is broken or missing.
Action
: Check the ADG Enabler Dongle. Replace if needed.
Cache Has Been Disabled; Likely Caused By a Loose Pin on One of the RAM Chips
Description
: Cache has been disabled due to a large number of ECC errors detected while testing the cache
during POST. This is probably caused by a loose pin on one of the RAM chips.
Action
: Try reseating the cache to the controller. If that does not work, replace the cache.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...