Error messages 159
1750-Fixed Disk 0 failed ID command
Audible Beeps
: None
Possible Cause
: Fixed drive error detected.
Action
: Run the server setup utility and correct the configuration.
1751-Fixed Disk 1 failed ID command
Audible Beeps
: None
Possible Cause
: Fixed drive error detected.
Action
: Run the server setup utility and correct the configuration.
1753-Slot X Drive Array - Array Controller Maximum Operating Temperature
Exceeded During Previous Power Up
Audible Beeps
: None
Possible Cause
: The controller is overheating.
Action
: Be sure adequate system cooling and sufficient airflow across the controller are available.
1754-Slot X Drive Array - One or more RAID levels are configured...
...but are not supported due to controller model or an inactive/missing license key. Please re-attach drives to original
controller or enter license key.
Audible Beeps
: None
Possible Cause
: The controller model does not support the configuration on the drives, or the license key is
inactive or missing.
Action
: Re-attach drives to the original controller, or enter a license key.
1756-Redundant controllers are not the same model
Audible Beeps
: None
Possible Causes
:
•
A Smart Array 3100ES Controller is paired with a 4250ES controller. In a redundant controller
configuration, both controllers must be the same model.
•
A defective system board or a controller is not fully seated in the PCI slot.
Action
:
•
If the controllers are different models, replace one of the controllers so they are both the same model.
•
Reseat the controllers.
CAUTION:
Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support
("
Contacting HP
" on page
187
) before proceeding.
•
If the problem persists, replace the system board.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...