Error messages 151
Audible Beeps
: None
Possible Cause
: A media error is detected on a drive and cannot be corrected because of degraded fault
tolerance or a media error at the same location on another drive in the same array. An unrecoverable read
error is returned to the operating system when this block address is read.
Action
: Backup and restore the data on the drive. Sequential write operations to the affected blocks should
resolve the media errors.
1717-Slot X Drive Array - Disk Drive(s) Reporting OVERHEATED Condition: Port X
Box Y Bay(s) Z
Audible Beeps
: None
Possible Cause
: The drives listed in this message are currently in an overheated state.
Action
: Check the fans and be sure the air flows over the drive. Install the access panel, if removed.
1718-Slot X Drive Array Device discovery found more devices attached to this
controller than firmware currently supports...
...Some devices are ignored.
Audible Beeps
: None
Possible Cause
: The firmware does not support the number of devices currently attached to the controller.
Action
:
•
If release notes indicate that support for additional devices has been added, upgrade to the latest
version of controller firmware.
•
Remove some of the devices attached to the controller.
1719-Slot X Drive Array - A controller failure event occurred prior to this power-up
(previous lock-up code = 0x####)
Audible Beeps
: None
Possible Cause
: A controller failure event occurred before the server powered up.
Action
: Install the latest version of controller firmware. If the condition persists, then replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect imminent failure: Port X
Box Y Bay(s) Z...
...
Do not replace drive unless all other drives in the array are online! Back up data before replacing drive(s) if using
RAID 0.
Audible Beeps
: None
Possible Cause
: A hard drive SMART predictive failure condition is detected. It may fail at some time in the
future.
Action
:
•
If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and
restore all data afterward.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...