Error messages 158
* Configuration information indicates one or more hard drive(s) are located in drive bays that are inaccessible when
the memory module is detached.
* Capacity Expansion operation(s) are pending but cannot continue because the Array Accelerator module has been
detached.
* ALL logical drive(s) have been disabled. To avoid data loss, upgrade controller or move the drives back to the
original controller. Run Array Configuration Utility to discard the current array and create new configuration
* Access to the following disk drives(s) has been disabled:
Select “F1” to continue disabling these drives until a new array configuration is created on them. To avoid data loss,
move these drives back to the original controller.
Select “F2” to reset configuration in these disk drives now.
Audible Beeps
: None
Possible Causes
:
•
The Array Accelerator memory module was removed or is defective.
•
The drives were moved to a controller that does not have an Array Accelerator memory module
attached.
Action
: Attach an Array Accelerator memory module to this controller, or move the drives back to the original
controller. If Capacity Expansion operations are pending, be sure that the original Array Accelerator module
is attached.
If all logical drives have been disabled, upgrade the controller or move the drives back to the original
controller to avoid data loss. Then, run ACU ("
Array Configuration Utility
" on page
72
) to discard the current
array and create a new configuration.
If access to specific drives has been disabled, do one of the following:
•
Press the
F1
key to continue disabling the drives until a new array configuration has been created. To
avoid data loss, move the drives back to the original controller.
•
Press the
F2
key to reset the configuration for the drives.
1748-Slot X Drive Array - Unsupported Array Accelerator Battery Attached...
...Please install battery pack(s) with the correct part number.
Audible Beeps
: None
Possible Cause
: The current battery pack is not supported on this Array Accelerator module.
Action
: Install only supported battery packs with the correct part number.
1749-Slot X Drive Array - Array Accelerator Flash Memory being erased...
...Accelerator will be reenabled when flash memory erase has completed.
Audible Beeps
: None
Possible Cause
: The Array Accelerator flash memory is being erased.
Action
: No action is required.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...