Error messages 150
Audible Beeps
: None
Possible Cause
: This configuration is not recommended because of controller memory requirements.
Action
: Perform RAID migration to lower stripe size using the Array Configuration Utility (on page
72
).
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but Array
Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number of
drives in the array, or upgrading the Array Accelerator module.
Audible Beeps
: None
Possible Cause
: Upgrade the Array Accelerator module to a larger size.
Action
: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot X Drive Array - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps
: None
Possible Cause
: Flash ROM is failing. The controller detects a checksum failure, but is unable to reprogram
the backup ROM.
Action
:
1.
Update the controller to the latest firmware version ("
Firmware maintenance
" on page
82
).
2.
If the problem persists, replace the controller.
1714-Slot X Drive Array - Redundant Checksum Error...
...Backup ROM has automatically been activated; check firmware version.
Audible Beeps
: None
Possible Cause
: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action
: If this backup ROM image is a lower version than the originally running image, update the controller
to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred...
...Warning: Corrected Memory Error(s) were detected during controller memory self-test. Please replace the controller
if this error persists.
Audible Beeps
: None
Possible Cause
: The memory is beginning to fail.
Action
: If this error persists, replace the controller.
1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during
previous Rebuild or Background Surface Analysis (ARM) scan...
...Errors will be fixed automatically when the sector(s) are overwritten. Backup and restore recommended.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...