Error messages 124
Audible Beeps
: None
Possible Cause
: This message indicates Online Spare Memory is enabled and indicates the amount of
memory reserved for this feature.
Action
: None.
Advanced Memory Protection mode: Multi-board mirrored memory with Advanced
ECC
...Xxxx MB System memory and xxxx MB memory reserved for Mirroring.
Audible Beeps
: None
Possible Cause
: This message indicates Mirrored Memory is enabled and indicates the amount of memory
reserved for this feature.
Action
: None.
Advanced Memory Protection mode: RAID memory with Advanced ECC
...Xxxx MB System memory and xxxx MB memory reserved for RAID.
Audible Beeps
: None
Possible Cause
: This message indicates RAID Memory is enabled and indicates the amount of memory
reserved for this feature.
Action
: None.
An Unexpected Shutdown occurred prior to this power-up
Audible Beeps
: None
Possible Cause
: The server shut down because of an unexpected event on the previous boot.
Action
: Check the System Management Log or OS Event Log for details on the failure.
Critical Error Occurred Prior to this Power-Up
Audible Beeps
: None
Possible Cause
: A catastrophic system error, which caused the server to crash, has been logged.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace failed components as
indicated.
Fan Solution Not Fully Redundant
Audible Beeps
:
Possible Cause
: The minimum number of required fans is installed, but some redundant fans are missing or
failed.
Action
: Install fans or replace failed fans to complete redundancy.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...