Error messages 161
Audible Beeps
: None
Possible Cause
: The current controller firmware does not support the attached Array Accelerator module
type.
Action
: Upgrade the controller firmware, or replace the Array Accelerator module.
1763-Slot X Drive Array - Array Accelerator daughtercard critical error; please
replace...
...(Controller is disabled until this problem is resolved)
Audible Beeps
: None
Possible Cause
: Array accelerator module is loose, missing, or defective.
Action
: Replace the array accelerator module.
1763-Slot X Drive Array - Array Accelerator module is detached; please reattach.
Audible Beeps
: None
Possible Cause
: Array accelerator module is loose, missing, or defective.
Action
:
1.
Reseat array accelerator module.
2.
If the problem persists, replace the array accelerator module.
1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...
(followed by one of the following:)
...Expansion will resume when Array Accelerator has been reattached.
* Expansion will resume when Array Accelerator has been replaced.
* Expansion will resume when Array Accelerator RAM allocation is successful.
* Expansion will resume when Array Accelerator battery/capacitor reaches full charge.
* Expansion will resume when Automatic Data Recovery has been Completed.
* Expansion will resume when Array Accelerator battery/capacitor is connected.
Audible Beeps
: None
Possible Cause
: The capacity expansion process has been temporarily disabled.
Action
: Follow the action that is displayed onscreen to resume the capacity expansion process.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps
: None
Possible Cause
: Power was lost while a logical expansion operation was performed. A controller reset or
power cycle occurs while array expansion is in progress.
Action
: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled due to Failure During Expansion...
(possibly followed by one of the following additional details:)
...* Array Accelerator Removed or Failed; Expansion Progress Data Lost.
* Expansion Progress Data Could Not Be Read From Array Accelerator.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...