Error messages 140
209-Mirror Memory Configuration - Memory Sizes on boards X and Y do not match
Audible Beeps
: 1 long, 1 short
Possible Cause
: The overall size of two boards participating in a mirrored configuration does not match.
Action
: Install or reinstall DIMMs to support mirrored mode.
209-RAID Memory Configuration - Memory Sizes on boards X and Y do not match
Audible Beeps
: 1 long, 1 short
Possible Cause
: The overall size of two boards participating in a RAID does not match.
Action
: Install or reinstall DIMMs to support RAID mode.
210-Memory Board Power Fault on board X
Audible Beeps
: 1 long, 1 short
Possible Cause
: A problem exists with a memory board powering up properly.
Action
: Exchange DIMMs and retest. Replace the memory board if problem persists.
210-Memory Board Failure on board X
Audible Beeps
: 1 long, 1 short
Possible Cause
: A problem exists with a memory board powering up properly.
Action
: Exchange DIMMs and retest. Replace the memory board if problem persists.
212-Processor Failed, Processor X
Audible Beeps
: 1 short
Possible Cause
: Processor in slot X failed.
Action
:
1.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
).
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page
18
)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
2.
Replace failed components as indicated.
214-Processor PPM Failed, Module X
Audible Beeps
: None
Possible Cause
: Indicated PPM failed.
Action
: Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
77
) and replace failed components as
indicated.
Содержание ML570 - ProLiant - 1 GB RAM
Страница 29: ...Diagnostic flowcharts 29...
Страница 33: ...Diagnostic flowcharts 33 Server and p Class server blade POST problems flowchart...
Страница 38: ...Diagnostic flowcharts 38 c Class server blade fault indications flowchart...
Страница 197: ...Acronyms and abbreviations 197 VCRM Version Control Repository Manager VGA video graphics array...