7 APPENDICES
7.1 APPENDIX A: TOOLS AND EQUIPMENT FOR INSTALLATION
Shown below is the list of the recommended tools for new installation and routine maintenance
Description
Slotted screwdriver
Phillips screwdriver
Ring spanner (M10)
Electrically operated drill and masonry drill bits
Anti-static wrist strap
Allen key
7.2 APPENDIX B: VSWR – RETURN LOSS TABLE
VSWR - Return Loss (dB)
(VSWR - RL)
VSWR - Return Loss (dB)
(VSWR - RL)
VSWR - Return Loss (dB)
(VSWR - RL)
1.4 -15.5
1.8 - 10.9
2.2 - 8.5
1.5 - 14
1.9 - 10.2
2.3 - 8.1
1.6 - 12.8
2.0 - 9.6
2.4 - 7.7
1.7 - 11.8
2.1 - 9
2.5 - 7.4
7.3 APPENDIX C: UPLINK ATT AND NOISE LEVEL
UL Master ATT
(dB)
UL Channel ATT
(dB)
200KHz Noise Level
(dBm)
0 0 -30
-10 0 -40
-20 0 -46
-30~-40 0 -48
-30~-40 -10 -55
-30~-40 -20 -63