4.7.1 DESCRIPTION OF PARAMETERS
The parameters being described are applicable to the RD-9120 variants.
4.7.1.1 NETWORK PARAMETERS
The following parameters are located on the left of the main screen, these include: Site Address, SMS and
data link parameters, all of enables communication with the OMC located in a Network Operation Centre.
SITE ADDRESS
The identification of each device site to the OMC. Valid ID must be a string
of unique six alphanumeric characters.
SMS REPORT ALARM
Specifies the SMS centre the system dial when alarms are to be sent as
short message.
The ‘OMC report number’ specifies a number the MCU to dial for alarm
reporting.
DATALINK REPORT
ALARM
In the datalink mode, alarms can be sent over the PSTN to a maximum of
four numbers.
Table 9: Management - Network Parameters
Note 1: Only one communication mode is available at one time. Green indicates active and red indicates
disable.
Note 2: If the alarm message has been acknowledged using OMT, then it would not be reported again.
In addition, in this window located the following buttons: ‘Online’, ‘DeviceReset’, ‘Firmware Update, ‘Read’,
‘Set’, ‘Enable and ‘Disable.
z
Online: click this button to connect the equipment to the OMT.
z
DeviceReset: click this button to reset the equipment
z
Firmware Update: click this button to download the MCU firmware.
z
Read: click this button to read the network parameters.
z
Set: enter the desired network parameters, and then click this button to admit the settings.
z
Enable: click this button to enable the communication mode.
z
Disable: click this button to disable the communication mode.