![COMBA RD-9120 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/comba/rd-9120/rd-9120_equipment-manual_2639092018.webp)
EQUIPMENT MANUAL FOR RD-9120
RD-9120 QE
Copyright - refer to title page
Page 18
ENU Status : 1-0-0
2.5 TECHNICAL SPECIFICATIONS
2.5.1 ELECTRICAL AND POWER
Model 1W
2W
10W
Electrical
Frequency Range, Uplink
MHz
890 – 915
Frequency Range, Downlink
MHz
935 – 960
Maximum System Gain
dB
92
±
2
Gain Adjustment Range (1dB step)
dB
0 – 30
Operating Bandwidth
MHz
2 – 24.6
Total Output Power
dBm
30
±
1
33
±
1
40
±
1
Downlink 3rd Order Intercept, OIP3
dBm
≥
54
≥
55
≥
54
Pass Band Ripple, p-p
dB
≤
4
System Noise Figure at Maximum Gain
dB
≤
5
System Group Delay
µ
sec
≤
6
Offset
≥
400KHz
≤
50
Offset
≥
600KHz
≤
40
Offset
≥
1MHz
≤
35
Out-of-band Gain at
System Gain
≤
80 dB
Offset
≥
5MHz
dBm
≤
25
9 KHz –1GHz
dBm
≤
-36
Spurious
1GHz – 12.75 GHz
dBm
≤
-30
Input VSWR
≤
1.5
Absolute Maximum RF Input Power
dBm
+10
Impedance
Ω
50
Power, Mechanical & Environmental
Dimensions, H x W x D
mm
600 x 450 x 195
Weight (approx.)
kg
37
Power Consumption
W
130
130
150
VAC
176 – 264 / 47 – 63Hz
Power Supply
VDC
+24 or -48
MCU Battery Backup Time (approx.)
hr
3
Power Up Waiting Time (approx.)
sec
60
Enclosure Cooling
Convection
RF Connectors
N-Female
Operating Temperature
°C
-40 to +55
Operating Humidity
%
≤
95
Environmental Class
IP65
MTBF hr
>
50,000
Typical specification at room temperature
Table 4: Electrical specifications