![COMBA RD-9120 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/comba/rd-9120/rd-9120_equipment-manual_2639092042.webp)
EQUIPMENT MANUAL FOR RD-9120
RD-9120 QE
Copyright - refer to title page
Page 42
ENU Status : 1-0-0
6 MAINTENANCE
The RD-9120 repeater offers trouble free operation and generally does not need maintenance.
The equipment operation status can be observed remotely through OMC.
Periodic inspection of the repeater equipment(s) is recommended, the recommended tasks includes:
z
Inspect and record operation status and output power of the repeater from OMC or OMT.
z
Verify the direction and position of antennas. Re-align if necessary.
z
Make sure the cable gland and sealing on the RF cable connectors are not damaged.
z
Verify lightning and grounding protection is in good condition.
z
For the Li-ion back-up battery, verify its state. Deeply discharged battery shall be return to Comba for
replacement.
¾
A simple procedure to check Li-ion battery: after operating for 24-hours, switch off AC power
supply. Measure and if the voltage of Li-ion battery drops below 16V within one hour, the Li-ion
battery has been over-discharged.
End of section