EQUIPMENT MANUAL FOR RD-9120
RD-9120 QE
Copyright - refer to title page
Page 36
ENU Status : 1-0-0
4.7.1.2 RF PARAMETERS
The RF parameters include: PW On/Off, Oscilation On/Off, master ATT (UL/DL), temperature, assistant
ATT (UL/DL), gain (read-only), uplink freq., downlink freq., VSWR threshold, power threshold (UL/DL) and
field threshold.
Identifier
Application
Setting 1
Setting 2
Initial setting
PW On/Off
To avoid the electro-magnetic
emission from the repeater in
operation, by enable/disable
the DC power supply to the
frequency selecting and
amplifying module. The
repeater gives out no power in
this case, but other parameters
are not affected.
‘ON' = DC power supply
enabled, and the
frequency selecting and
amplifying module is
enabled, parameters of
which can be set and
read.
‘OFF’= no DC
supply to frequency
selecting and
amplifying module.
their parameters
(frequency band,
ATT, power, and
alarm) can not be
read or set.
ON
Oscillation
On/off
To enable/disable the function
that controls self-excited
oscillation
‘ON' = enable the
function to control the
self-excited oscillation,
this is done automatically
by stepping down the
gain when while isolation
value is lower than the
configured value.
‘OFF = disable the
function to control
the self-excited
oscillation.
OFF
ATT setting
Adjustment to the operation
gain for: Master
uplink/downlink ATT, assistant
uplink/ downlink ATT.
Master uplink / downlink
ATT is 0~30dB
Assistant uplink /
downlink ATT is
0~10dB.
0dB for both
master ATT &
Assistant ATT
Temperature
threshold
Setting the upper-temperature
threshold within the enclosure.
A measured temperature is
shown.
Should the measured
temperature reach the
threshold, the alarm is
generated.
+80c
Channel number
setting
To configure channel number,
and the offset freq.
Uplink channel numbers:
High edge and low edge
Downlink channel
numbers: High edge
and low edge
Output Power
Low Threshold
To set the uplink and downlink
output power low threshold. A
measured power level is
shown, and customer can set
power threshold according to
situation. It is suggested to set
the threshold 3~5dBm lower
than the measured values.
Should the measured
power value is lower than
the setting, the
appropriate UL/DL power
low alarm will be
generated.
Input Power Low
Threshold
To set the input power low
threshold. A measured power
level is shown, and customer
can set power threshold
according to situation.
Should the measured
power value is lower than
the setting, the
appropriate alarm will be
generated.
Table 10: Management - RF parameters