Note:
ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Controller address
– user adjustable number from 0 to 255, which defines address used by controller for
communication with the module. Controller can use different address for communication with different
modules. Default option is Default (X), X stands for actual address value, which comes from ESC and is
used by controller interface for communication with module, when the default option is used. N/A is
displayed as
Controller address
, if Modbus is used for communication with a module.
Note:
Do not confuse Controller address with Comms settings: Contr.address, which is different parameter
with independent functionality.
Note:
ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Protection upon module failure
– use it to select type of alarm, which is issued if communication with
module fails
Add screens
– use it to display/hide module related screens
Display data as
– information how are analog values displayed
Analog inputs
– Number of analog input values available with module.
Note:
Total number of available analog input values is limited to 160 with all configured modules (e.g. 4
modules with 40 inputs would use all available inputs).
Analog outputs
– Number of analog output values available with module.
Note:
Total number of available analog output values is limited to 40 with all configured modules (e.g. 5
modules with 8 outputs would use all available outputs).
Binary inputs
– Number of binary input values available with module.
Note:
Total number of available binary input values is limited to 160 with all configured modules (e.g. 4 modules
with 40 inputs would use all available inputs).
Binary outputs
– Number of binary output values available with module.
Note:
Total number of available binary output values is limited to 160 with all configured modules (e.g. 4
modules with 40 outputs would use all available outputs).
Analog inputs (4B)
– Number of 4B analog input values available with module.
Note:
Total number of available 4B analog input values is limited to 20 with all configured modules (e.g. 5
modules with 4 inputs would use all available inputs).
Содержание InteliDrive DCU Marine
Страница 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Страница 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Страница 104: ...InteliDrive DCU Marine 3 0 0 Global Guide 104 8 Appendix 8 1 Controller objects 105 6 back to Table of contents ...
Страница 242: ...InteliDrive DCU Marine 3 0 0 Global Guide 242 Binary output to J1939 configuration Source Value 8 1 5 Analog Inputs ...
Страница 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Страница 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Страница 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...