InteliDrive DCU Marine - 3.0.0 Global Guide
123
Engine params
Setpoint group
Engine params
Related FW
3.0.0
Range [units]
30 .. 1500 [RPM]
Default value
350
Step
1
Comm object
9095
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
“Firing” speed when controller stops cranking = one of the engine running indications.
Note:
Under speed limit is fix 30 RPM.
Starting RPM