InteliDrive DCU Marine - 3.0.0 Global Guide
60
Note:
Incorrect polarity of the binary output connection may cause a damage of the binary outputs.
4.3.7 Binary output separation
In some special cases e.g. when Relays plus terminal is disconnected via EMERGENCY STOP contact, the
binary outputs must be separated using diodes to avoid false Binary output LED indication.
In the Example below when EMERGENCY STOP contact is opened, the BO3 LED should light (without
separating diode SD3) even if the BO3 output is opened.