Page | 63
VASTRAJET
14. Error Handling
Error Code
Error Description
Error Description
400100D1
Print position overrun
Please try to print images or narrow
width or increase printing the origin
position.
400100F6
Encoder Error!
Problem in Encoder Sensor and Scale
400100FC
Touch limit sensor
Jumpers are connected
04020002
Pumping cyan
Low ink level in tank
04020003
Pumping magenta
Low ink level in tank
04020004
Pumping yellow
Low ink level in tank
04020005
Pumping black
Low ink level in tank
04020008
Incorrect input in the Time Limit Password or
may consist the forbidden character
Re-input correct password.
04020009
Illegal time-limit of the password
Re-input correct password.
0402000A
Time limit password and manufacturer ID
doesn’t matched
Re-input correct password.
0402000B
Time limit password and board ID doesn’t
matched
Re-input correct password.
0402000C
First Warning:
100 hours left against current
time-limit password
Request for a new time password
from the dealer.
0402000D
Second Warning:
50 hours left against current
time-limit password
Request for a new time password
from the dealer.
0402000E
Last Warning:
1 hour left against current time-
limit password. After this, issue job gets
stopped
Request for a new time password
from the dealer immediately.
04020021
Print data is more than fire number
•
Encoder Scale/Sensor is not
aligned
•
Encoder Scale is having ink stains
•
Incorrect pulley is used
•
Servo
Driver
programmed
incorrectly
•
Incorrect print mode is selected
•
Main Board settings are incorrect
•
Pulley/Belt teeth are wear out
04020034
Pump ink overtime
Low ink level and warning is enabled
in Printer Manager.
20020002
Motion COM timeout
LVDS is loose or faulty.
20020003
Head board COM timeout
LVDS is loose or faulty.
20020004
Print data mismatch with fire
Kindly refer to the error code
04020021.
40020001
Data header error.
USB and common earthing related
issue.
40020009
Image too width.
Kindly refer to the error code
400100D1.
4002000C
Head board Step 1