Industrivej 62
DK-6740 Bramming
Denmark
Original
Version:
1.0
IceTech R1000H
Alarm List
Page:
3 of 5
Date:
01.05.18
Init:
JM
60 Error , high temperature feeder motor
15
61 Error, Shuttle 1 homing
16
62 Error, Ejector 1 homing
16
63 Error, Shuttle 2 homing
16
64 Error, Ejector 2 homing
16
65 Overheat , Unit 1
17
66 Overheat , Unit 2
17
67 Motor Overheat Unit 1
18
68 Motor Overheat Unit 2
18
69 Alarm ID=17744 , MAIN.X01.G01.U1.M1
19
70 Alarm ID=17744 , MAIN.X01.G01.U2.M1
19
71 Alarm ID=17744 , MAIN.X01.G02.U1.M1
19
72 Alarm ID=17744 , MAIN.X01.G02.U2.M1
19
Trouble shooting table
Troubleshooting Alarm test
Description
1
Emergency_Stop
Emergency stop is active.
Release emergency stop or replace component if damaged.
2
Error
Program error
Contact IceTech technical support.
3
Bus Error
Hardware error
Contact IceTech technical support.
4
Max_ActionTime
Max. actiontime
Contact IceTech technical support.
5
MCB
Error on main circuit breaker.
Check if the main circuit is engaged and if the is a short
circuit / components failure causing the MCB to trip out.
6
Timeout
Timeout.
Investigate what’s causing timeout on component.
7
Sensor failure hopper
Capacitive sensors on the hopper is not active in correct
order.
Check if hopper is blocked or if sensor sensitivity needs to be
Содержание 514635
Страница 1: ...User s Manual Technical file 1 2 User s manual IceTech R1000H...
Страница 2: ...User s Manual 1 User s manual IceTech R1000H...
Страница 27: ...Technical file 2 User s manual IceTech R1000H...
Страница 29: ...Table for mechanical maintenance 1 Technical File IceTech R1000H...
Страница 33: ...Procedures for maintenance and repair 2 Technical File IceTech R1000H...
Страница 66: ...Alarm list 3 Technical File IceTech R1000H...
Страница 72: ...P I Diagram 4 Technical File IceTech R1000H...
Страница 77: ...Assembly drawings 5 Technical File IceTech R1000H...