IceTech R1000H
Procedures for Maintenance and Repair
Page:
8-26 of
32
Date:
24.08.18
Init:
JM
8. PROCEDURE FOR CHANGING HYDRAULIC OIL HYDRAULIC STATION
During this operation it’s important to activate the emergency stop button!
Procedure step by step
1.
Remove the oil. Drain out off this ball valve
[
1
]
. The used oil must be deposited at an
approved station for environmental waste.
2.
Clean the hydraulic tank
[
2
]
inside by removing the cover plate
[
3
]
on the tank side.
3.
Reassemble the hydraulic tank.
4.
Put (270 Litres R1000H) “DTE Mobil FM 46 approved for food manufacturing” in the
hydraulic tank.
Notice: If there are no demand for oil approved for food manufacturing, this oil can be used DTE 10 XL
46.
BEFORE STARTING PRODUCTION THE HYDRAULIC STATION SHOULD BE CHECKED IN SINGLE MODE!
1. Ball valve
3. Cover plate
2. Hydraulic tank