Industrivej 62
DK-6740 Bramming
Denmark
Original
Revision:
2.0
IceTech R1000H
Procedures for Maintenance and Repair
Page:
10-30 of
32
Date:
24.08.18
Init:
JM
10.
PROCEDURE
FOR REPLACING DIVERTER CYLINDER
Before changing the diverter cylinder
[
1
]
make sure that R1000H is in E-stop state or shut down and that
pneumatic air is disconnected. Remove air hoses and disconnect reed sensors. Loosen the 6 screws on
the taper bush
[
5
]
and the 2 screws on the foot mount
[
2
]
for the pneumatic cylinder
[
1
]
. Pull the entire
cylinder assembly off and replace with new parts from stock. Slide the taper bush
[
5
]
on the diverter
plate shaft and install the foot mount
[
2
]
on the bracket. Adjust the cylinder plus stroke and diverter
plate so there are a few millimeter gap between the hopper wall and the diverter plate. Check the
return position of the cylinder that there also is a few millimeter gap on the opposite side between the
hopper wall and the diverter plate. Tighten the taper bush. Connect reed sensors and check the
adjustment of the reed sensors.
After installing the new diverter cylinder check the operation in single mode:
Operating in single mode control
1 Select single mode
2 Enter Manual operation
controls
1
2
3
4
5
Содержание 514635
Страница 1: ...User s Manual Technical file 1 2 User s manual IceTech R1000H...
Страница 2: ...User s Manual 1 User s manual IceTech R1000H...
Страница 27: ...Technical file 2 User s manual IceTech R1000H...
Страница 29: ...Table for mechanical maintenance 1 Technical File IceTech R1000H...
Страница 33: ...Procedures for maintenance and repair 2 Technical File IceTech R1000H...
Страница 66: ...Alarm list 3 Technical File IceTech R1000H...
Страница 72: ...P I Diagram 4 Technical File IceTech R1000H...
Страница 77: ...Assembly drawings 5 Technical File IceTech R1000H...