Industrivej 62
DK-6740 Bramming
Denmark
Original
Revision:
2.0
IceTech R1000H
Procedures for Maintenance and Repair
Page:
5-18 of
32
Date:
24.08.18
Init:
JM
Remove the rotation guard
[
1
]
by loosening the three
bolts
[
2
]
using an 8mm Allen wrench.
Remove the cables for the linear encoder
[
3
]
and loosen the encoder using a 46mm wrench.
Replace the hydraulic cylinder
Support the hydraulic cylinder with a hoist or a forklift, and make sure that it’s possible to lift it out of
the machine frame. Remove and plug the hydraulic hoses. The hydraulic cylinder is removed by
loosening the 4 super bolts
[
4
]
.
Hoist the new cylinder in and place standing on the upper bracket. Tighten the 4 pcs. super bolts loosely,
and make sure that the cylinder is level and in line with the press chamber. Final alignments are to be
made after installing the press piston. Fit the rotation guard and torque tighten the three bolts
[
2
]
to
20,3 Nm. Reinstall the press piston. Reconnect the hydraulic hoses and plug in the linear encoder.
2
1
3
4