Where,
1) Daily event or block event selector. A daily event would happen
everyday at the specified time. A Block event would happen
continuously between the two times specified.
2) Is the Start time in 24 hr format
3) Is the Stop time in 24 hr format.
4) Is the start day of the week for this timed event.
5) Is the stop day of the week for this timed event.
6) Is the event type which can be FLUSH, FREE (Free vend mode),
TMD INH (Timed Inhibit).
For example, to inhibit the machine each day between 5 and 6 pm you could set up
the timed event as follows,
DAY. 1700 1800
SUN>SAT TMD INH
To enter free vend mode during weekdays between 12 and 1 pm you could set the
timed event as,
DAY. 1200 1300
MON>FRI FREE
To inhibit the machine over a weekend you could write,
BLOK. 1700 FRI >
0800 MON TMD INH
T
ANK
S
TATUS
38.
The TANK STATUS option allows the engineer to view the status of the boiler water level
and temperature in both the Instant and Espresso boilers.
Press ENTER to display the tank status. The display will show:
WET 92°C 0447
G: WER 92 °C 0577
The top row refers to the Instant boiler, showing either WET or Dry, the temperature i.e.
Содержание VITRO X3
Страница 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Страница 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Страница 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Страница 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Страница 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Страница 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Страница 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Страница 69: ......