COFFEtek
LTD
53
23/02/17
Issue 1
VITRO X3
DAILY HYGIENE
Cleaning (Instant & Espresso)
22.
This process should be carried out a minimum of three times a day.
Set the On/Off switch on the machine to ON.
Remove the instant ingredient canisters. Wipe clean the exterior surfaces of the
canister assembly. Wipe dry.
Remove the coffee grouts bucket. Empty the contents of the bucket and wash and
dry it.
Remove the waste tray and grille. Empty the contents of the tray and wash and dry
the tray and grille.
Put a container of at least 300ml capacity under the dispensing nozzles.
Press the FLUSH button once on the internal keypad. The screen will ask if you wish
to flush the espresso system. Press ENTER for YES.
The machine will flush warm clean water through the tea brewer, once finished the
espresso group will move to a three quarter position and flush warm clean water
though this into the grout bin. Finally the machine will run warm clean water through
the instant bowl whilst running the whipper motor. This process will clean any residual
product that has been left in any of the systems.
Once again remove the coffee grouts bucket. Empty the contents of the bucket and
wash and dry it then refit into the machine.
Содержание VITRO X3
Страница 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Страница 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Страница 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Страница 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Страница 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Страница 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Страница 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Страница 69: ......