CONNECTING THE ELECTRICAL SERVICES
WARNINGS (1)
THE MACHINE MAINS CABLE MUST BE CONNECTED TO THE SUPPLY
VIA A SAFETY ISOLATOR SWITCH WHICH PROVIDES A CONTACT
SEPARATION OF AT LEAST 3mm.
(2)
REPLACEMENT OF THE Y TYPE MAINS CABLE REQUIRES SPECIAL
TOOLS. SHOULD THE CABLE BECOME DAMAGED, REPLACEMENT
MUST ONLY BE CARRIED OUT BY A TRAINED PERSON FROM AN
APPROVED SERVICE AGENT.
(3)
ENSURE THAT THE SUPPLY TO THE ISOLATOR SWITCH IS ISOLATED
BEFORE MAKING ANY CONNECTIONS TO IT.
(4)
ENSURE THAT THE SUPPLY TO THE BEVERAGE MACHINE IS ISOLATED
BEFORE MAKING ANY CONNECTIONS TO THE TERMINAL BLOCK AT
THE REAR OF THE MACHINE.
(5)
THE BEVERAGE MACHINE MUST BE EARTHED.
13.
The mains cable fitted to the machine should be 3-core, depending on the electrical supply
available and the number of heaters to be connected in circuit. The cable is terminated at a
terminal block at the base of the machine. Connection to the electrical supply must not be
carried out using a cable with more cores than required.
14.
Do not attempt to connect more than one heater to a 230V~, 10A or 16A single phase
supply. The mains cable must be connected to the supply via a safety isolator switch,
preferably located behind the machine. Ensure that the supply to the isolator switch is
isolated before making the connections. Ensure that the supply to the beverage machine is
isolated before making any connections to the terminal block. The machine must be
earthed.
15.
Connect the beverage machine, via a safety isolator switch with a contact separation of at
least 3mm, to a 230V~, 50Hz, 13A supply. Note that replacement of the Y Type mains
cable requires special tools. Should the cable become damaged, replacement must only
be carried out by a trained person from an approved service agent.
To reconfigure the machine to operate from a 110V supply, move the voltage selector
link on the PSU to the 110V position and replace the 240V 3kW element (part no. 12345)
with a 110V 1.6kW element (part no. 56223).
16.
Preferably, the isolator switch should be located behind the machine to prevent accidental
damage or misuse.
17.
The number of heaters which can be connected in circuit depends on the supply available.
The supply requirements are as follows.
Содержание VITRO X3
Страница 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Страница 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Страница 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Страница 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Страница 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Страница 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Страница 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Страница 69: ......