COFFEtek
LTD
33
23/02/17
Issue 1
VITRO X3
M
ACHINE
S
ETTINGS
41.
Settings
Description
OUT
OF
SERVICE
0
Enables machine to be programmed out of
service:
Setting this to 1 sets the machine out of service
GLOBAL
SCALING
100
Adjustment of cup volume of drinks. All aspects of drink are scaled, i.e.
product, whipper, water.
DRY VEND FLAG
0
Enables product only operation:
0 = Water On, 1 = Water Off
SERIAL
NUMBERS
The machines serial number can be entered so that it can be viewed on the
LCD display. By default this facility is disabled.
BEHAVIOUR
CODE
Status Display, STANDARD being the default.
BEHAVIOUR 1
– Debug setting for Coffetek Software engineers only.
FLUSH TIME OUT
– The machine will function normally until the number of
hours set in the FLUSH TIME HRS
setting passes then the machine will inhibit all the vends until the machine has
been flushed.
COLD WATER OUT
– If the machine is fitted with a chiller kit to produce cold
vends.
EXTERNAL PUMP
– If the machine is fitted with an external pump kit i.e.
Whale Pump.
INGRED MONITOR
– Will allow the machine to monitor how much product is
being dispensed per drink to prevent a purely water vend being produced.
EXT WASTE SENSOR
– If the machine is fitted to a base cabinet or side unit
with a waste kit to remove the coffee grouts and water this heading must be
turned on.
STATUS
DISPLAY
001
Will show on the internal display what the machines current boiler status is
Содержание VITRO X3
Страница 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Страница 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Страница 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Страница 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Страница 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Страница 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Страница 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Страница 69: ......