FAULT
POSSIBLE CAUSE
ACTION
Heater tank
not filling
Heater tank
boiling over
Heater tank
overfilling
Bearding of ingredient
Machine floods
No display
TEMP LOW
displayed
(a)
Low water pressure
(b)
Inlet valve fault
(c)
MPU Board fault
(a)
Incorrect
desired
temperature setting
(b)
Temperature probe fault
(c)
MPU Board fault
(d)
Short on solid state relay
(a)
Probe open circuit
(b)
Inlet valve fault
(c)
Level
probe
incorrectly
positioned
(a)
Extractor fan fault
(b)
Steam hoods missing from
mixing bowls or incorrectly
positioned
(a)
Dispense pipes incorrectly
fitted to dispense head
(b)
Mixing bowls incorrectly
fitted
(c)
Whipper seals missing
(d)
Overflow pipe incorrectly
fitted
(a)
Display connector loose
(a)
Thermal cut-out tripped
(b)
Heater fuse blown
(c)
Incorrect
temperature
setting
(a)
Check water pressure
(b)
Check inlet valve
(c)
Replace MPU Board
(a)
Reset desired temperature
setting
(b)
Replace probe
(c)
Replace MPU board
(d)
Replace relay
(a)
Check probe circuit
(b)
Check inlet valve
and replace if necessary
(c)
Reposition probe
(a)
Check fan
(b)
Fit steam hoods to mixing
bowls
and
position
correctly.
(a)
Reposition pipes
(b)
Reposition mixing bowls
(c)
Check seals
(d)
Refit overflow pipe
(a)
Refit connector
(a)
Reset cut-out
(b)
Check fuse
(c)
Check program setting
Содержание VITRO X3
Страница 1: ...VITRO X3 BEVERAGE MACHINE TECHNICAL MANUAL ...
Страница 5: ...COFFEtek LTD 5 23 02 17 Issue 1 VITRO X3 This page is intentionally blank ...
Страница 61: ...COFFEtek LTD 61 23 02 17 Issue 1 VITRO X3 Section 4 Exploded Parts Diagram ...
Страница 62: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 62 ...
Страница 63: ...COFFEtek LTD 63 23 02 17 Issue 1 VITRO X3 ...
Страница 64: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 64 ...
Страница 65: ...COFFEtek LTD 65 23 02 17 Issue 1 VITRO X3 ...
Страница 66: ...COFFEtek LTD VITRO X3 Issue 1 23 02 17 66 ...
Страница 69: ......