11
23/02/17
Issue 1
VITRO X3
is OFF and the other one toggles ON & OFF unless a boost operation is in progress then both
SSR are ON.
If the actual temperature is between 35 - & 50 less than the desired temperature one SSR is
ON and the other is OFF. Boost operations are as above.
If the actual temperature is more than 50
below the desired temperature both SSR’s are ON.
The Espresso system also has a boost control which operation takes place when the heater
control is instructed to turn on the
SSR’s for the duration specified in the variable GRP
OVRDRVE TIME referred to Section 2 paragraph 24.
The GRP OVEDRVE TIME is located in the CHANGE SETTINGS menu. If a coffee based
vend has not produced from the machine inside the specified time of the GRP OVERDRVE
TIME the next coffee based vend produced from the machine will heat the Espresso boiler to
the specified GRP OVRDRVE TEMP from the CHANGE SETTINGS MENU to ensure a cooler
vend is not to be produced