Pas sen ger Com part ment Con nec tions (Con tin ued)
Dual Park ing Light Cir cuit (Most Euro pean Ve hi cles)
1. Turn on the parking lights and access the Parking Light wiring in one of the following
locations:
n
Near the head light switch
n
In the door sill har ness go ing to the rear lights
n
At any of the four Park ing Light bulbs
2. If working underdash, be sure to turn the dashlight dimmer to its lowest setting.
3. Connect a voltmeter lead to ground and find the two wires that show +12v when the
parking lights are on and 0 volts when they are off.
4. Connect one lead to the left-side Parking Light circuit and connect the other lead to the
right side circuit.
NOTE: Never con nect the RED/WHITE wire to ground. Al ways pick up the
positive- switching park ing light line(s).
Aux il iary A with Se lecta ble Out put Type
The Auxiliary A output (GRAY/VIOLET wire) can be programmed as either pulsed, latched
or timed and can be programmed to operate only when the system is armed (e.g., for use as a
remote trunk release). Auxiliary A output is activated by pressing the
button on the
remote control. The factory setting is pulsed output (0.5 second ground). The latched output
stays at ground until the
button is pressed a second time, and the timed output stays at
ground for any selected duration between one second and four minutes. See
Installer-Programmable Features
on page 16 for information on programming the output type
and/or disabling operation while the system is disarmed.
Aux il iary B with Se lecta ble Out put Type and AutoAc ti va tion
The Auxiliary B output (GRAY/BLUE wire) can be programmed as either pulsed, latched or
timed. It can also be programmed to automatically activate every time the system is remotely
armed. The output is activated by pressing the
button on the remote. Current is limited to
0.25 amp. AutoActivation is perfect when programmed as a timed-output to close the power
windows and sunroof on vehicles that have an all-close feature (see the
Window Control
section of
this manual for more information on wiring this feature). See
Installer-Programmable Features
on
page 16 for more information on programming output type and/or enabling the
AutoActivation feature.
9