© 2007 directed electronics
11
* This feature is not evaluated by Thatcham.
N
NO
OTTEE:: The current handling capacity of each immobilisation circuit is 20 amps con-
tinuous and 30 amps peak.
h4 connector (female)
Connect the BLACK wires H4/1 and H4/2 to separate ground locations using a fac-
tory bolt that does NOT have any vehicle component grounds attached to it or drill a
new hole if required. A screw should only be used in conjunction with a two-sided
lock washer. Under dash brackets and door sheet metal are not acceptable ground
points.
BLACK - H4/4
(+) 12V Input
BLACK - H4/2
Ground
BLACK - H4/1
Ground
BLACK - H4/3 Indicator
Light Flash Input
H3/4 Ignition Car Side
H3/3 Ignition Key Side
H3/2 Starter Key Side
H3/1 Starter Side
x
CUT
x
CUT
Starter
Ignition