7.
Adjust Warn-away zone
z
Press .
z
Siren chirps 2 times.
z
Sensor adjustment mode is entered.
z
Hit vehicle at the desired level of impact.
z
Sensor adjusts itself to the force of Hit.
z
Siren chirps 1 time as confirmation of adjustment.
z
Press
to lock adjustment.
8.
Press
to re-enter Primary zone adjustment
z
Siren chirps 2 times.
z
Primary zone can now be re-adjusted as described in #4.
z
Or press
again to exit programming mode.
z
The siren will chirp 3 times when sensor adjustment mode has been exited.
second unlock feature
ON: System will monitor disarm channel for 10 seconds after disarm, if disarm chan-
nel is again transmitted within 10 seconds, H1/15 Blue/white will generate the
programmed unlock output.
OFF: H1/12 Blue/white wire will generate the programmed unlock pulse at the same
time as first unlock.
auto-immobilisation feature
Immobiliser circuits automatically activate after 30 seconds.
N
NO
OTTEE:: H1/12 orange ground when armed will not activate during Auto-
Immobilisation
auto-immobilisation sequence
1.
Turn ignition off or disarm alarm
2.
After 30 seconds the systems Immobilisation circuits activate and engage the
starter and ignition interrupt
3.
LED flashes at ½ normal speeds.
Disarm the system when immobilised
Use one of the following methods to turn off auto-immobilisation
z
Turn ignition on and press the
button of the transmitter.
z
Arm the alarm and then disarm the alarm.
z
Turn the ignition on and enter the system valet/PIN code.