background image

SPECIFICATIONS:

Detection Type: 

 

Photoelectric Chamber
Power Source:   

 

Built-in DC3V (CR123A) Lithium battery 
(Non-replaceable battery) 
Standby Current 

 

<8uA 

Alarm Current 

 

<70mA

Alarm Sound Level   

>85dB at 3 metres

Alarm Sensitivity 

 

0.09 - 0.15dB/m 

Hush Time 

 

Approx. 10 mins

Operation Temperature 

5°C to 45°C

Ambient Humidity   

up to 85%

Sound Pattern:  
ISO8201(BI0.5s - pause 0.5s - BI 0.5s - pause 
0.5s - BI 0.5s - pause 1.5s, with the red LED 
flash, repeat this alarm pattern). 
Compliance Standard  

 AS3786:2014

The unit is a photoelectric 3V DC smoke alarm. 
Photoelectric technology is more sensitive to 
detecting slow smouldering fires which are 
generally thick with black smoke, little heat and 
may smoulder for hours before bursting into 
flames. This smoke alarm does not contain 
radioactive material.

IMPORTANT:

 This manual contains important 

information about the installation and operation of 
your smoke alarm. Please read carefully before 
installation and keep for future reference. Please 
ensure that this leaflet remains in the household 
where the alarm is installed.

WARNING: 

This smoke alarm is designed to alert 

you to the presence of smoke. It cannot prevent a 
fire. There are hazards against which smoke 
alarms may not be effective such as smoking in 
bed, explosions, etc.  The ultimate responsibility 
for fire protection rests with you. This 
responsibility includes escape planning, safety 
checks and an effective warning system. In case 
of fire, a well placed, properly looked after smoke 
alarm may provide a few seconds so that you can 
escape and call the fire brigade.

IMPORTANT SAFETY INFORMATION

1. This smoke alarm has an inbuilt Lithium battery 
that does not require servicing or changing. This 
battery is a 10 year maintenance free battery that 
is not accessible to the user. This battery must be 
operational to operate the alarm correctly. To test 
the battery press the test button on this    
smoke alarm.

2. 

DO NOT

 connect this smoke alarm to any 

other type of smoke alarm  The test button 
accurately tests all smoke alarm functions.                             

3. The Test button accurately tests all smoke 
alarm functions. 

DO NOT 

use any other test 

method. Test smoke alarm weekly to ensure 
proper operation.

4. 

DO NOT

 remove or disconnect battery to 

silence unwanted alarms. This will remove your 
protection. Use the Hush Feature, open windows 
or ventilate the smoke alarm to silence it.

5. This smoke alarm may be installed by a 
licensed, qualified electrician or a competent 
individual. Observe and follow all local and 
national electrical and building codes for 
installation.

6. This smoke alarm is designed to be used 
inside a single unit dwelling only. In buildings with 
several dwellings, each individual living unit 
should have its own smoke alarms. 

DO NOT

 

install in non-residential buildings. This smoke 
alarm is not a substitute for a complete alarm 
system.

7. Install a smoke alarm in every room and on 
every level of the home. Smoke may not reach the 
smoke alarm for many reasons. For example, if a 
fire starts in a remote part of the home, on another 
level, in a chimney, wall, roof or on the other side 
of a closed door. Smoke may not reach the smoke 
alarm in time to alert household members. A 
smoke alarm will not promptly detect a fire except 
in the area or room in which it is installed.

8. Smoke alarms may not alert every household 
member every time. The alarm sound is loud in 
order to alert individuals to a potential danger. 
However, there may be limiting circumstances 
where a household member may not hear the 
alarm (i.e. outdoor or indoor noise, sound 
sleepers, drug or alcohol usage, hard of hearing, 
etc.). If you suspect that this smoke alarm may not 
alert household members, install and maintain 
specialty alarms. Household members must hear 
the alarm’s warning sound and respond, to quickly 
reduce the risk of damage, injury or death that 
may result from fire. If a household member is 
hearing impaired, install special smoke alarms 
with lights or vibrating devices to alert occupants.

9. Smoke alarms can only sound their alarms 
when they detect smoke. Smoke alarms detect 
combustion particles in the air. They do not sense 
heat, flame or gas. This smoke alarm is designed 
to give an audible warning of a developing fire. 
However, many fires are fast burning, explosive or 
intentional. Others are caused by carelessness or 
safety hazards. Smoke may not reach the smoke 
alarm quickly enough to ensure safe escape.

10. Smoke alarms have limitations. This smoke 
alarm is not foolproof and is not warranted to 
protect lives or property from fire. Smoke alarms 
are not a substitute for insurance. Homeowners 
and renters should insure their lives and property. 
In addition, it is possible for the smoke alarm to fail 
at any time. For this reason, you must test the 
smoke alarm weekly and replace every 10 years.

NOTE: 

For best protection, we recommend that 

you install a smoke alarm in every room.

WHERE TO INSTALL YOUR ALARM 

For best safety, install smoke alarms in every 
room: Including hallways, bedrooms, living 
rooms, attics & basement. At the very least, one 
smoke alarm on every floor.

SMOKE ALARM PLACEMENT

Typical single-storey home 

Install a smoke alarm on the ceiling or wall inside 
each bedroom and in the hallway outside each 
separate sleeping area. If a bedroom area or 
hallway is more than 9 metres (30 feet) long, 
install a smoke alarm at each end. If there is a 
basement, install a smoke alarm on the basement 
ceiling at the bottom of the stairwell.

 

  

Typical Multi-storey or split level home  

Install a smoke alarm on the ceiling or wall inside 
each bedroom and in the hallway outside each 
separate sleeping area. If a bedroom area or 
hallway is more than 9 metres (30ft) long, install a 
smoke alarm at each end. Please install a smoke 
alarm on the top of a first-to-second floor stairwell.

RECOMMENDED PLACEMENT OF SMOKE 
ALARMS

Locate a smoke alarm in any area where a smoker 
sleeps or where electrical appliances are operated 
in sleeping areas.

Smoke, heat and other combustion products rise 
to the ceiling and spread horizontally. Mounting 
the smoke alarm on the ceiling in the centre of the 
room places it closest to all the points in the room. 
Ceiling mounting is preferred in ordinary 
residential construction. However, in mobile 
homes, wall mounting on an inside partition is 
preferred to avoid the thermal barrier that may 
form in the ceiling.

AS3786:2014

 Lic SMKH25550

SAI Global

BEDROOM

HALL

BEDROOM

LIVING ROOM

KITCHEN

BASEMENT

MULTI-STOREY RESIDENCE

KEY: 

Minimum required smoke alarm locations 

Recommended additional smoke alarm locations   

Smoke alarms with hush features recommended
for additional protection     

Heat and

smoke

from fire

Best here

Dead air space,

do not install here

300mm
minimum

300mm minimum

Dead air space,
do not install here

900mm

minimum

Best here

FFPDCH10Y

PHOTOELECTRIC SMOKE ALARM WITH

10 YEAR LITHIUM BATTERY

TEST & HUSH BUTTON

DINING ROOM

LIVING ROOM

BEDROOM

BEDROOM

KITCHEN

SINGLE-STOREY RESIDENCE, APARTMENT, MOBILE HOME