background image

STATEMENT OF RESPONSIBILITIES /

DÉCLARATION DES RESPONSABILITÉS / 

DECLARACIÓN DE RESPONSABILIDADES

This document is for use by experienced
and trained Qualified Cleveland Range,
LLC Authorized Service Representatives
who are familiar with both the safety
procedures, and equipment they
service. Cleveland Range, LLC assumes
no liability for any death, injury,
equipment damage, or property damage
resulting from use of, improper use of,
or failure to use the information
contained in this document. Cleveland
Range, LLC has made every effort to
provide accurate information in this
document, but cannot guarantee that
this document does not contain
unintentional errors and omissions.

The information in this document may
be subject to technical and
technological changes, revisions, or
updates. Cleveland Range, LLC
assumes no liability or responsibility
regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to follow industry standard
safety procedures, including, but not
limited to, OSHA regulations, and
disconnect / lock out / tag out
procedures for all utilities including
steam, and disconnect / lock out / tag
out procedures for gas, electric, and
steam powered equipment and / or
appliances.

All utilities (gas, electric, water and
steam) should be turned OFF to the
equipment and locked out of operation
according to OSHA approved practices
during any servicing of Cleveland Range
equipment

Qualified Cleveland Range, LLC
Authorized Service Representatives are
obligated to maintain up-to-date
knowledge, skills, materials and
equipment. 

Ce document est destiné à l’usage des
Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC qui
possèdent l’expérience et la formation ainsi
que la bonne connaissance des mesures
de sécurité et du matériel qu’ils
entretiennent.

Cleveland Range, LLC décline toute
responsabilité pour tout cas de décès,
blessure, dommage matériel ou dommage
aux biens résultant de l'utilisation, de la
mauvaise utilisation ou du manquement
d’utilisation des renseignements contenus
dans ce document.

Cleveland Range, LLC s’est efforcé à
fournir des renseignements précis dans ce
document mais ne peut garantir que ce
document soit exempt d’erreurs et
d’omissions non intentionnelles. 

Les renseignements contenus dans ce
document peuvent être assujettis à des
changements techniques et technologiques,
des révisions ou des mises à jour. 

Cleveland Range, LLC décline toute
obligation ou responsabilité concernant les
errata, modifications, révisions ou mises à
jour.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus de se conformer aux mesures de
sécurité normalisées de l’industrie, y
compris, mais sans s'y limiter, les
réglementations de l'OSHA, les procédures
de  débranchement / verrouillage /
étiquetage relatives à tous les services
publics, dont l’approvisionnement en
vapeur, et les procédures de
débranchement / verrouillage / étiquetage
relatives aux équipements et/ou appareils
fonctionnant au gaz, à l’électricité et à la
vapeur.

Au cours de tout entretien d’un appareil
Cleveland Range, tous les services publics
(gaz, électricité, eau et vapeur) doivent être
FERMÉS au niveau de l’appareil et le
dispositif de fonctionnement doit être
verrouillé suivant les pratiques approuvées
de l’OSHA.

Les Représentants de Service qualifiés et
autorisés de Cleveland Range, LLC sont
tenus d’actualiser en permanence leurs
connaissances, compétences, matériel et
équipement.

Este documento está destinado para el uso
de los Representantes de Servicio
calificados y autorizados de Cleveland
Range, LLC quienes cuentan con la
experiencia y la capacitación así como el
buen conocimiento de las medidas de
seguridad y de los equipos que mantienen. 

Cleveland Range, LLC, declina toda
responsabilidad en caso de cualquier
fallecimiento, lesiones, daños al equipo o
daños a la propiedad resultantes de la
utilización, del uso indebido o de la falta de
utilización de la información provista en este
documento.

Cleveland Range, LLC se ha esforzado en
suministrar información precisa en este
documento, pero no puede garantizar que
este documento esté exento de errores y de
omisiones no intencionales.

La información contenida en este
documento podría estar sujeta a cambios
técnicos o tecnológicos, revisiones o
actualizaciones.  Cleveland Range, LLC
declina toda obligación o responsabilidad
con respecto a erratas, modificaciones,
revisiones o actualizaciones.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de seguir los procedimientos
estándar de seguridad de la industria; los
cuales incluyen pero no se limitan a los
reglamentos de la OSHA (La Administración
de la Seguridad y Salud Ocupacionales), los
procedimientos de desconexión, cierre y
etiquetado relativos a todos los servicios
públicos incluyendo el suministro de vapor y
los procedimientos de desconexión, cierre y
etiquetado para los equipos y/o aparatos
que funcionan a base de gas, electricidad o
vapor.

Cuando se esté dando servicio o
mantenimiento a un aparato de Cleveland
Range, todos los servicios públicos (gas,
electricidad, agua y vapor) deben estar
APAGADOS para el equipo en cuestión y se
debe seguir el procedimiento de cierre de
operaciones de acuerdo con las prácticas
aprobadas por la OSHA.

Los Representantes de Servicio calificados y
autorizados de Cleveland Range, LLC tienen
la obligación de actualizar constantemente
sus conocimientos, destrezas, materiales y
equipamiento.

Содержание SteamChef 22CCT6

Страница 1: ...E004049 2 B Operation Installation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual MODELS 22CCT6 For your future reference Model ______________________________________ Serial ___________ ____________________________ Visit www clevelandrange com to locate a service or sales representative in your area ...

Страница 2: ...ormer aux mesures de sécurité normalisées de l industrie y compris mais sans s y limiter les réglementations de l OSHA les procédures de débranchement verrouillage étiquetage relatives à tous les services publics dont l approvisionnement en vapeur et les procédures de débranchement verrouillage étiquetage relatives aux équipements et ou appareils fonctionnant au gaz à l électricité et à la vapeur ...

Страница 3: ...ación ajuste modificación servicio o mantenimiento puede ocasionar daños a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operación antes de instalar poner a funcionar o dar servicio a este equipo PARA SU SEGURIDAD No guarde ni use gasolina o cualesquiera otros líquidos o vapores inflamables en las cercanías de éste o cualquier otro aparato No pulverice aero...

Страница 4: ...ón Keep clear of pressure relief discharge Restez à l écart de la soupape de sureté Permanezca alejado de la descarga de presión Do not lean on or place objects on the equipment Ne vous penchez pas sur oune placez pas des objets sur la lèvre No se apoye ni coloque objetos en el labio Inspect unit daily for proper operation Inspectez l unité tous les jours pour son bon fonctionnement Inspeccione di...

Страница 5: ...Operation 5 C Main External Power Switch 6 D Inspecting the Cooking Compartment 6 E Manual Water Fill 6 F Door Interlock Switch 7 G Install Remove the KleanShield 7 H Install the Fan Guard Air Diverter 8 I Install Remove the Slide Racks Pan Racks 8 J Install Remove the Bypass Shield 8 K High Limit Reset 9 L Water Refill 9 4 Cooking 10 A Quick Reference Start Up and Shutdown Summary Instructions 10...

Страница 6: ... the Appliance 17 D Electric Power Supply 17 E Installation Checklist 18 7 Startup Procedure 19 A Startup Instructions 19 B Shutdown Instructions 19 8 Operating Tests 20 A Startup Procedure with the Appliance De Energized 20 B Operating Test for Dial Timer 21 C Operating Test for Electronic Timer 22 D General Information about the Steam Shut Off Switch 24 E Function Test for the Steam Shut Off Swi...

Страница 7: ...lumbing codes 3 Installation instructions must be read in their entirety before starting installation of this appliance 4 Install this appliance according to the policies and procedures outlined in this manual 5 Installation must comply with all local fire and health codes B Operational Safety The Operational Safety section outlines minimum safety policies and procedures for operating one or more ...

Страница 8: ...rd features and options available on this appliance Other than the selection of options there are presently no significant design parts or operating differences among appliances with this model numbers For further information contact your Cleveland Range sales representative or Cleveland Range B MODEL NUMBERS AND SERIAL NUMBERS 1 Cleveland Range LLC assigns two product identification numbers to ea...

Страница 9: ...ionless Chef Product View 22CCT6 Shown Figure 2 1 Connectionless Chef Steam Cooker Side Panel Operating Controls ON OFF Switch Condensate Vent Rating Plate on Rear Panel Drain Valve Drain Pan Guides with Drain Pan ...

Страница 10: ...partment is at cooking temperature 3 The buzzer sounds when the Timer reaches zero 6 ON OFF Switch The ON OFF switch controls electric power to the control panel Pressing the ON right end of the switch energizes the steamer control panel The red indicator on the switch lights and all the safety controls become active Pressing the OFF left end of the switch deactivates all control circuits and the ...

Страница 11: ...become active Pressing the OFF left end of the switch deactivates all control circuits and the red indicator goes out The high limit circuit is reset if it had been activated 5 RESET Indicator Indicator lights Red when the High Limit circuit trips The Red light stays ON and a buzzer sounds until the appliance is reset To reset 1 Turn OFF power to the steamer with the Power ON OFF Switch 2 Wait 15 ...

Страница 12: ...ean and free of any residue or debris See Figure 3 4 5 Make sure there is an empty drain pan 4 X 12 X 20 in the drain pan rack and the KleanShield drain is clear by pouring about a quart of water through the KleanShield drain See Figure 3 6 and 3 7 Make sure that the water flows out the steamer drain into the drain pan 6 Inspect and clean the drain before each use See Figure 3 5 E Manual Water Fil...

Страница 13: ...ough pipe slips into the drain pipe at the right side of the cooking compartment 3 Carefully lower the front of the KleanShield so the Water Level Sensor Guard is behind the probes and the front legs rest on the bottom of the cooking compartment To Remove the KleanShield turn off the Connectionless Chef and wait for it to cool remove the pan racks carefully lift the front of the KleanShield lift t...

Страница 14: ...ks See Figure 3 9 Each rack has four loops two top and two bottom 1 Hold the slide rack so the ends of the hanger loops are towards compartment wall 2 Slide one rack into the cooking compartment with the loop side closest to the compartment wall and rack slots horizontal 3 Hook the loops over the top and bottom pins 4 Repeat steps 1 2 and 3 for the other rack J Install Remove the Bypass Shield Not...

Страница 15: ...roblem repeats see the Operators Troubleshooting Guide Chapter 7 L Water Refill During operation water level will slowly decrease Once water level falls below the center probe the Green ADD WATER indicator light will come on to let the user know to fill the reservoir During this time the Connectionless Chef will continue to cook until the water level reaches below the left probe Heat Probe Once th...

Страница 16: ...stalled Start Up if the Main External Power Switch is OFF 1 Turn the ON OFF switch OFF 2 Turn ON the Main External Power Switch 3 When ready to start heating turn ON the ON OFF Switch See Figures 3 1 and 3 2 4 Cook as usual Start Up if the Main External Power Switch is ON 1 When ready to start heating turn ON the ON OFF Switch See Figures 3 1 and 3 2 2 Cook as usual Shutdown 1 Turn OFF the ON OFF ...

Страница 17: ...to prevent burns scalds and other injuries d See Timed Mode and Manual Mode and the Control Panels Figures 3 1 3 2 as required 4 After Cooking a If the appliance will be used again in a few minutes shut door to maintain cooking compartment temperature b If the appliance will not be used again during this shift go to Chapter 5 Cleaning C TIMED MODE OPERATING AND COOKING PROCEDURE For DIAL Timer uni...

Страница 18: ... CLEAR button a new time can be entered to start another cooking cycle 9 Open the cooking compartment door and remove the pans from the slide racks D MANUAL MODE OPERATING AND COOKING PROCEDURE In Manual Mode the Operator starts and stops steaming operations Use Manual Mode for o Maintaining cooking compartment temperature between cooking batches o Continuous supply of steam 1 Set the TIMED MANUAL...

Страница 19: ... 5 SHUTDOWN AND CLEANING A SHUTDOWN AND CLEANING PROCEDURE This procedure should be performed at the end of each day shift or more often if needed The steamer stays hot for a long time To help avoid burns Allow the steamer to cool completely before cleaning or servicing Do NOT use hoses power cleaners or pressure washers on or in the Connectionless Chef Steamer Doing so can cause electric shock an...

Страница 20: ... scale from the steamer 8 Wipe down the interior of the cooking compartment with a half water and half white household vinegar solution Use a spray bottle of the same vinegar solution to rinse the convection fan located at the back of the cooking compartment When done daily this will help prevent the buildup of calcium and other mineral deposits left over from the boiling of water and prevent scal...

Страница 21: ...the retaining pins into the keyhole slots Either long edge of the gasket assembly can be positioned at the top Periodic rotating of the door assembly will help increase the door gasket life 14 Replace the cleaned KleanShield slide racks and fan guard See Chapter 3 15 Wipe the exterior with a damp cloth only 16 NEVER HOSE DOWN THE STEAMER Electrical components inside the unit will not function corr...

Страница 22: ... for Shipping Damage If the appliance is damaged or damage is suspected 1 Submit a Damage Claim to the Shipper immediately 2 Inform your dealer at once 3 Inform Cleveland Range in writing within three 3 days f KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLES g Proper air supply for ventilation is REQUIRED for and CRITICAL to safe efficient operation of this appliance h Make sure the air vent...

Страница 23: ...lectrical and wiring requirements specified on the rating plate NOTE The 22CCT6 Electrical Diagrams are located on the backs of the right side panel The connection must be made as follows 1 Install a main disconnect switch and a separate fuse or breaker for this appliance as shown in Figure 3 6 The fused disconnect switch is called the Main External Power Switch 2 Make the electrical connection us...

Страница 24: ... Page Number COMPLETED Initial and Date Preparation Check Operating Location Clearances Figure 1 1 Pg 2 Electric Power Requirements Met Rating Plate Pg 7 Installation Pg 3 4 Check Level Front to Back and Side to Side Pg 4 Check Electrical Supply Connection Pg 7 Notes ...

Страница 25: ...STARTUP PROCEDURE Problems See the Installer s Troubleshooting Guide at the end of this manual Startup Test Startup and Shutdown Instructions NOTE Perform this test before the Startup Procedure and Operating Tests A Startup Instructions 1 Turn the Main External Power Switch OFF 2 Control Panel Settings a ON OFF switch OFF b MANUAL TIMED Switch TIMED c TIMER DIAL 0 minutes If dial timer model 3 Tur...

Страница 26: ... the appliance being installed For high altitude use above 3500 feet contact Cleveland Range at 216 481 4900 about parts and adjustments required A Startup Procedure with the Appliance De Energized 1 Start with or the Main External Power Switch OFF 2 Check the fuses or circuit breakers for proper size 3 Open the cooking compartment door Make sure the drain is not blocked The drain valve should be ...

Страница 27: ...ain power switch ON ON OFF switch ON The red indicator on the switch is lit TIMED MANUAL switch TIMED Timer 0 If the Timer is not zeroed turn the dial counterclockwise to the 0 mark Door Open 4 Set the TIMED MANUAL switch to MANUAL Nothing will happen as long as the door is open 5 Close the steamer door the steaming cycle starts 6 Check the following functions The door interlock switch makes conta...

Страница 28: ...tup Procedure the Operating Test procedure and the Steam Shut Off Test procedure the steamer is ready for use 17 Refer the Operator s Manual for complete operating instructions C Operating Test For Keypad Control Note Temperatures need to be adjusted for high altitude use above 3500 feet Contact Cleveland Range at 216 481 4900 about parts and adjustments required Note Make sure the KleanShield Fan...

Страница 29: ... compartment door for 3 minutes to allow the cooking compartment to cool 9 After 3 minutes close the door and continue testing 10 Set the TIMED MANUAL to TIMED and set the Timer for 10 minutes by entering 1 0 0 0 on the keypad and press the START STOP button 11 As soon as the display no longer reads PAUS the steam generating cycle starts and the timer counts down 12 After the timed operation has b...

Страница 30: ...turn on until the cooking compartment reaches cooking temperature If fan or heating elements do not start Shut down the appliance and call your qualified Cleveland Range authorized service representative 8 After completing the Initial Startup Procedure the Operating Test procedure and the Door Interlock Switch Test procedure the steamer is ready for use Refer to the Operator s Manual for complete ...

Страница 31: ... water may become dirty from spills falling over the edge of pans when loading cooking and emptying the steamer Change the water see below when the water becomes cloudy or contaminated with food particles CHANGE THE WATER IN THE CONNECTIONLESS CHEF STEAMER AT LEAST EVERY DAY IN ORDER TO MAINTAIN FOOD QUALITY AND KEEP THE STEAMER SANITARY Note It may be necessary to change the water several times a...

Страница 32: ...bber gloves splash goggles and other protective clothing and equipment as necessary Refer to Dissolve container labels and Material Safety Data Sheets for information regarding eyewash first aid medical treatment and spill control DANGER The liquid solution in Cleveland Range Descaler Solution Part No 106174 can be harmful if not handled properly Follow these basic safety rules for handling and us...

Страница 33: ...aking them in a solution of 1 part Dissolve and 4 parts water rinsing thoroughly with cold water and washing them in a dishwasher 6 Remove any loose scale from the bottom of the steamer 7 Leave the Connectionless Chef OFF and the door open NOTE DO NOT HEAT THE STEAMER DURING DESCALING 8 Pour 1 to 1 quarts about a third of a 1 gallon bottle of DISSOLVE descaler solution into the water reservoir Whi...

Страница 34: ...ion repeats see Note 1 Bottom of reservoir is heavily scaled See Note 1 or 9 Inoperative controls See Note 1 Steam and or water leaking around the compartment door Water level too high Drain excess water The drain to the KleanShield opening is clogged or covered Clear collector openings Figure 3 7 If condition persists see Note 1 Door gasket or door parts worn See Note 1 Appliance not level See No...

Страница 35: ...and Range at 216 481 4900 for preventative maintenance programs descaling kits descaling information and water treatment systems 8 To evaluate whether this appliance operating at normal cooking performance conduct the Egg Test NOTE This test is not valid for pressure steamers a Place a perforated steam table pan in the middle rack position in the cooking compartment b Turn ON the appliance and set...

Страница 36: ...kitchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every new piece of Welbilt Foodservice equipment comes with KitchenCare and you choose the level of service that meets your opera onal needs from one restaurant to mul ple loca ons 2016 Welbilt Foodservice ...

Отзывы: