7
Never operate a Connectionless Chef without the KleanShield
properly installed.
The properly installed KleanShield™ helps protect the operator from scalding water
splashing out of the reservoir, and helps prevent drain blockage.
Operating a Connectionless Chef without the KleanShield™ properly installed can
cause injury, equipment damage, and reduce performance.
6. Check the water after every steaming operation and add water or, if the water has become dirty,
drain and refill as needed.
F. Door Interlock Switch
The steamer compartment of the Connectionless Chef Steamer is equipped with an automatic
door interlock switch that turns off the heating elements and shuts off the convection fan
when the door to the compartment is opened.
G. Install/Remove the KleanShield
•
Note: The KleanShield™ is dishwasher safe.
•
To
Install
the KleanShield
:
1. Remove the pan racks.
2. Place the KleanShield
into the Connectionless Chef so the drain trough pipe slips into the
drain pipe at the right side of the cooking compartment.
3. Carefully lower the front of the KleanShield™ so the Water Level Sensor Guard is behind
the probes and the front legs rest on the bottom of the cooking compartment.
•
To
Remove
the KleanShield
, turn off the Connectionless Chef and wait for it to cool, remove the
pan racks, carefully lift the front of the KleanShield
, lift the drain trough pipe from the drain pipe,
and remove the KleanShield™ from the cooking compartment.
Figure 3-6
KleanShield
Burn and Scald Hazard
Even though the heat shuts off as soon as the door is opened, it may take up to a minute for production of
steam to end and residual steam in the system to clear from the cooking compartment.
To help avoid injury, always wait until the residual steam clears and the convection fan stops before
reaching into the cooking compartment, and always wear dry heatproof gloves when reaching into the
cooking compartment. Wet or damp gloves conduct heat and can cause burns when touching hot items.
Failure to do so can cause burns, scalds, and other injuries.
Figure 3-7
KleanShield
Installation