2
3
•
Nothing will happen as long as the door is open.
5.
Close the steamer door, the steaming cycle starts.
6.
Check the following functions.
•
The door interlock switch makes contact.
•
The heating elements are energized.
•
The water in the steam generator reservoir boils in a few minutes.
•
Steam is visible intermittently coming from the steam vent (the small pipe extension at the
right rear on the steamer’s back).
•
The cooking compartment reaches cooking temperature, and the heating elements cycle on
and off as the thermostat maintains cooking temperature.
•
In Manual mode, the appliance will cook continuously until turned off, or set to the Timed
mode.
•
After several minutes of steaming, check for steam leaks around the door gasket.
7.
Set the TIMED/MANUAL switch to TIMED.
•
The steam generating cycle stops.
•
The heating elements turn off.
8.
Open the cooking compartment door for 3 minutes to allow the cooking compartment to cool.
9.
After 3 minutes, close the door and continue testing.
10. Set the TIMED/MANUAL to TIMED, and set the Timer for 10 minutes by entering 1-0-0-0 on the
keypad and press the START/STOP button.
11. As soon as the display no longer reads “PAUS”, the steam generating cycle starts and the timer
counts down.
12. After the timed operation has been started, observe the following steam generating functions.
•
The timer begins counting down to zero.
•
Check for steam leaks around the door.
•
When the timer counts down to zero, the heating elements turn off, and the alarm sounds
continuously until the START/STOP button is pressed.
13. Turn the ON/OFF switch OFF. (The red indicator light turns off.)
14. Turn the steamer off at the Main External Power Switch.
15. Replace the side panel.
16. After completing the Initial Startup Procedure, the Operating Test procedure and the Steam Shut
Off Test procedure, the steamer is ready for use.
17. Refer the Operator’s Manual for complete operating instructions.