2
2
•
The heating elements and the Heat On indicator turn off.
•
The alarm sounds for 3 seconds.
8. Open the cooking compartment door for 3 minutes to allow the cooking compartment to cool.
9. After 3 minutes, close the door and continue testing.
10. Set the TIMED/MANUAL to TIMED, and set the Timer for 10 minutes.
11. As soon as the dial is set, the steam generating cycle starts.
•
This is the same sequence as Manual operation except:
o
The timer controls the cycle.
o
The elapsed time to produce steam is shorter because the water in the steam-cooking
compartment is already hot.
12. After the timed operation has been started, observe the following steam generating functions.
•
The timer immediately begins counting down to zero.
•
Check for steam leaks around the door.
•
When the timer counts down to zero, the heating elements, and the buzzer sounds for 3
seconds.
13. Turn the ON/OFF switch OFF. The red indicator light turns off.
14. Turn the steamer off at the Main External Power Switch.
15. Replace the side panel.
16. After completing the Initial Startup Procedure, the Operating Test procedure and the Steam Shut
Off Test procedure, the steamer is ready for use.
17. Refer the Operator’s Manual for complete operating instructions.
C. Operating Test For Keypad Control
Note: Temperatures need to be adjusted for high altitude use (above 3500 feet). Contact Cleveland
Range at 216-481-4900 about parts and adjustments required.
Note: Make sure the KleanShield
, Fan Guard, and drain pan are installed prior to testing.
1.
Turn ON the Main External Power Switch.
2. Turn ON the ON/OFF switch.
•
The control panel energizes, the Green “ADD
WATER” indicator light turns ON, and the buzzer
sounds continuously.
•
Add 3 quarts of fresh water to the reservoir. (Do
NOT use distilled water.) The Add Water buzzer
will turn OFF.
•
Add an additional 2 1/4 gallons of fresh water to
the reservoir. (Do NOT use distilled water.) The
Green “ADD WATER” indicator light will turn OFF.
•
The “ADD WATER” alarm and indicator will turn ON whenever the water level drops below
the water sensors located at the lower right front of the steamers interior. (See Figure 4-1.)
3.
Set the controls:
•
Main power switch: ON.
•
ON/OFF switch: ON (The red indicator on the switch is lit).
•
TIMED/MANUAL switch: TIMED.
•
Door: Open
4.
Set the TIMED/MANUAL switch to MANUAL.