Safety
6
2.4.
Safety devices
MAXIMUM PRESSURE:
The maximum operating pressure that can be set is 8
bar.
There is a double pressure control:
• one is a pressure sensor, via the control system, which shuts down the generator
when pressure values exceed 0.5 bar (set value);
• a pressure switch, independent of the control system, limits the pressure to 11
bar.
HYDROGEN-AIR MIXTURE:
The formation of a potentially hazardous hydro-
gen-air mixture inside the generator is prevented by a forced ventilation system.
If the ventilation system fails to operate, a dedicated sensor makes the genera-
tor stop.
Any significant gas leaks are also indicated by the line pressure control system.