Fault list
72
11.3.
List of Warnings
Warnings indicate situations which may require the work of a Claind specialized
technician or, if they are easy to resolve, a guided procedure is prompted by the
CPU.
The warnings with their cause and resolution are listed below.
Warni
ng
Description
Cause
Resolution
W-00
Data loss
The memory has lost the set
parameters and is using the
default values
Contact technical assistance
(par. 2.5. Technical Assistance)
W-01
Filling sequence
timeout
Active water reserve
1) Fill the reserve tank with
demineralized water
(par. 4. Demineralized water)
W-02
Circulation tank
empty
Circulation tank running low
1) Fill the reserve tank with
demineralized water
(par. 4. Demineralized water)
W-03
Desiccant exhausted expected desiccant lifetime over
Carry out the guided sequence
prompted by the CPU
(par. 10.6. Changing desiccant)
W-04
Pump lifetime elap-
sed
expected pump lifetime over
Contact technical assistance
(par. 2.5. Technical Assistance)
W-05 Poor water resistivity
Demineralized water with low
resistivity
Replace water in reserve tank
W-06 Reserve tank empty
Reserve tank empty
1) Fill the reserve tank with
demineralized water
(par. 4. Demineralized water)
W-07 Clock data loss
Extended power failure
Record time
W-08
Temperature sensor
fault
Failure of the electronic box
temperature sensor
Contact technical assistance
(par. 2.5. Technical Assistance)
W-09
Temperature sensor
fault
Failure of the current generator
temperature sensor
Contact technical assistance
(par. 2.5. Technical Assistance)
W-10
Reserved
-
-
W-11
Reserved
-
-
W-12
Reserved
-
-
W-13
Resistivity sensor
fault
The resistivity sensor is not
responding
Contact technical assistance
(par. 2.5. Technical Assistance)
W-14 Resin bed exhausted
The Resin bed has exhausted its
period of operation
Carry out the guided sequence
prompted by the CPU (par. 10.7.
Resin bed replacement)
W-15
Depressurization
timeout
Generator depressurization has
failed
Contact technical assistance
(par. 2.5. Technical Assistance)