Hydrogen generator
HyGen
23
After draining, disconnect the coupler.
TIME REQUIRED: approximately 1 minute
6.6.2.
Reserve tank draining
To drain the reserve tank, carry out the following operations:
• Disconnect the tank both electrically and pneumatically by removing the jack and
the quick coupling (C);
e
During the step described above, warnings will appear which will then disappear
after reconnecting the tank.
• physically remove the tank and empty it after removing the plug (D);
• screw the plug (D) back in, put the tank back into place, reconnect it by inserting
the jack and the quick coupling (C) and fit the front panel back on.
A
B
A
B
C