Hydrogen generator
HyGen
65
After making the connection, touch the “>>” button to go to the third step;
• this step asks you to replace the Resin bed;
• locate the Resin bed (A), disconnect the two quick couplings (B) by pressing on
the clips (C) and extract it from the ring collar (D);
• Replace it with the new Resin bed, taking care over the position of the arrow
(upwards) on the body, and reconnect the pneumatic connections;
e
The new Resin bed is isolated from the external environment by diaphragms on
the caps; to use it you have to break them by firmly pressing on the quick cou-
plings on it.
e
Check that the expiry date printed on the Resin bed is at least six months after
today's date.